800G SR8 and 400G SR4 Optical Transceiver Modules Compatibility and Interconnection Test Report

VersionChange LogWriter
V0Sample TestCassie

Test Purpose

Test Objects:800G OSFP SR8/400G OSFP SR4/400G Q112 SR4. By conducting corresponding tests, the test parameters meet the relevant industry standards, and the test modules can be normally used for Nvidia (Mellanox) MQM9790 switch, Nvidia (Mellanox) ConnectX-7 network card and Nvidia (Mellanox) BlueField-3, laying a foundation for subsequent cooperation with customers.

Test Items

ItemsDetails
Hardware Compatibility TestPlug Test-DeviceThe module can be plugged and unplugged for more than 5 times and can be matched with the slots of Nvidia (Mellanox) MQM9790 switch and Nvidia (Mellanox) ConnectX-7 ports, and there is no looseness or jamming of the module.
Port Reboot TestThe link can be restored in 5 minutes after power failure and reboot of the equipment.
Software Compatibility TestConnectivity TestThe module can connect to both devices with the status of the device ports being up.
Parameter TestThe information of PN, VN, SN and DDM of the module read by the device is consistent with the description of the module label.
Long-term BER Test7*24 hours Pre-BER (<1e-6) and Post-BER (<1e-12) are as expected.
Interconnection Test1. Nvidia (Mellanox) 800G To FiberMall 400G module link up BER on the equipment meets the requirement.
2. FiberMall 800G To mallonox 400G module in equipment link up BER meets the requirement.

Test Conclusions

  • FiberMall 800G OSFP SR8/400G Q112 SR4/400G OSFP SR4 modules meet the requirements for interface compatibility with Nvidia (Mellanox) Switch 9790, Nvidia (Mellanox) ConnectX-7 NIC and Nvidia (Mellanox) BlueField-3 DPU.
  • FiberMall 800G OSFP SR8/400G Q112 SR4/400G OSFP SR4 modules and Nvidia (Mellanox) 800G OSFP SR8/400G Q112 SR4/400G OSFP SR4 modules have been running traffic service for a long time, and the long-term BER test meets the requirements.

Test Environment

Test Samples

ManufacturerPNSpecificationSerial No.
FiberMallOSFP-800G-SR8D800G OSFP 850nm 100mMT233320036
OSFP-400G-SR4-FLT400G OSFP 850nm 50m MT233320018
MT233320020
QSFP112-400G-SR4400G QSFP112 850nm 100mMT233250003
MT233250018
MT233250015
MT233250020
Nvidia (Mellanox)MMA4Z00-NS800G OSFP SR8 50mMT2304FT11726
MMA4Z00-NS400400G OSFP SR4 50mMT2304FT19441
MT2304FT13582
MMA1Z00-NS400400G QSFP 112 SR4 50mMT2305FT04288
MT2302FT20690
MT2252FT06234
MT2307FT01145

Test Devices

BrandModelSoftware Version (running)
Nvidia (Mellanox)Nvidia (Mellanox) ConnectX-728.38.0368
Nvidia (Mellanox)Nvidia (Mellanox) MQM9790mft 4.21.0-99
Nvidia (Mellanox)Nvidia (Mellanox) BlueField-3/

Test Topological Graph

800G OSFP SR8 to 400G OSFP SR4
800G OSFP SR8 to 400G QSFP112

Test Data

Hardware Compatibility Test

Test Methods1. Plug and unplug the switch ports more than 5 times continuously.
2. Record whether each plug and unplug test matches the port slot.
3. Check whether there is any looseness or jamming of 400G OSFP SR4/800G OSFP SR8/400G QSFP112 SR4 on the device port.
4. Power off and reboot the switch 5 times, and record whether the link is restored after each switch reboot.
Test ConditionsTest itemTest Times
12345
Plug normallyPassPassPassPassPass
No loosenessPassPassPassPassPass
No jammingPassPassPassPassPass
Link restoredPassPassPassPassPass
Test ConclusionAfter testing:
1. 400G OSFP SR4/800G OSFP SR8/400G QSFP112 SR4 can be plugged into the ports on both sides of the device. The modules are inserted into the ports and are tightly bonded to the device ports, with no signs of loosening of the modules. The module can be unloaded from the port by pulling the module pull ring without any jamming.
2. The link is restored within 5 minutes after each power failure and reboot of the switch.

Software Compatibility Test

Test Methods1. Check if the device status is normal.
2. Check if the port LED of the device is green.
3. Check if the device port is linking up normally.
4. Check if the device port rate is up to standard.
 Port StatusActive
Port Link RateIB-NDR
Test ConclusionAfter testing, 400G OSFP SR4/800G OSFP SR8/400G QSFP112 SR4 connect normally on Nvidia (Mellanox) 9790 switch, Nvidia (Mellanox) ConnectX-7 and BlueField-3, the LEDs of the device ports at both ends are always green, and the link is up.
Test MethodsVendorFiberMall
1. Check whether the basic information such as module vendor name, model name, and serial number is correct.
2. Check whether the key parameters of the module such as transmission distance, wavelength, and type are correct.
3. Check whether the DDM parameters of the module have exceeded the threshold.
PNOSFP-800G-SR8DOSFP-400G-SR4-FLTOSFP-400G-SR4-FLT
Serial numberMT233320036MT233320018MT233320020
Wavelength (nm)858858858
Transmission Distance (m)100100100
DDM Temperature(°C)505353
DDM Voltage(mV)3272.83284.73298.3
DDM Bias Current(mA)8.34,8.52,8.44,8.608.54,8.60,8.63,8.668.44,8.48,8.50,8.60
DDM Tx Optical Power(dBm)2,2,2,22,2,2,22,2,2,2
DDM Rx Optical Power(dBm)2,2,2,22,2,2,22,2,2,2
 Test ConclusionAfter testing, FiberMall 800G OSFP SR8/400G OSFP SR4 can recognize the vendor name, model name, serial number, DDM and other information on Nvidia (Mellanox) 9790 switches and Nvidia (Mellanox) ConnectX-7 cards, and the modules operate normally.
Test MethodsVendorFiberMall
1. Check whether the basic information such as module vendor name, model name, and serial number are correct.
2. Check whether the key parameters of the module such as transmission distance, wavelength and type are correct.
3. Check whether the DDM parameters of the module have exceeded the threshold.
PNQSFP112-400G-SR4
Serial numberMT233250003MT233250018MT233250015MT233250020
Wavelength (nm)853853853853
Transmission Distance (m)100100100100
DDM Temperature(℃)60585957
DDM Voltage(mV)3291.63303.93303.13299.3
DDM Bias Current(mA)8.50,8.528.630,8.6608.440,8.4808.340,8.400
DDM Tx Optical Power(dBm)2,2,2,2,2,22,2,
DDM Rx Optical Power(dBm)2,2,2,2,0,22,2,
Test ConclusionAfter testing, the FiberMall  400G QSFP112 SR4 recognizes the vendor name, model name, serial number, and DDM information on Nvidia (Mellanox) 9790 switches and Nvidia (Mellanox) BlueField-3 DPUs, and the module operates normally.

Long-term BER Test

Test ItemsFiberMallFiberMall
OSFP-800G-SR8DOSFP-400G-SR4-FLT
MT233320036MT233320018MT233320020
Test Duration168H168H168H168H
Pre-BER(<1e-6)YesYesYesYes
Post-BER (<1e-12)YesYesYesYes
 ConclusionFiberMall 800G OSFP SR8 to FiberMall 400G OSFP SR4 runs continuously for 7*24 hours on Nvidia (Mellanox) 9790 switch and Nvidia (Mellanox) ConnectX-7 NIC Pre-BER (<1e-6), Post-BER (<1e-12). As expected, no link interruption during the period, no abnormality in module docking.
Test ItemsFiberMallFiberMall
OSFP-800G-SR8DQSFP112-400G-SR4
MT233320036MT233250003MT233250018MT233250015MT233250020
Test Duration168H168H168H168H168H
Pre-BER(<1e-6)YesYesYesYesYes
Post-BER (<1e-12)YesYesYesYesYes
 ConclusionFiberMall 800G OSFP SR8 to FiberMall 400G Q112 SR4 on Nvidia (Mellanox) 9790 switches and BlueField-3 DPUs running continuously for 7*24 hours Pre-BER (<1e-6), Post-BER (<1e-12) as expected, with no link outages during the period. No module docking anomalies.

Interconnection Test

FiberMall 800G OSFP SR8 to Nvidia (Mellanox) 400G OSFP SR4

Test MethodsFiberMallNvidia (Mellanox)
OSFP-800G-SR8DMMA4Z00-NS400
MT233320036MT2304FT19441MT2304FT13582
Check if FiberMall 800G OSFP SR8 To Nvidia (Mellanox) 400G OSFP SR4 module is linked up on the device.Link upLink upLink up
Test Duration72H72H72H
Pre-BER(<1e-6)YesYesYes
Post-BER (<1e-12)YesYesYes
ConclusionFiberMall 800G OSFP SR8 To Nvidia (Mellanox) 400G OSFP SR4 module in Nvidia (Mellanox) 9790 switch and Nvidia (Mellanox) ConnectX-7 NIC Link up, BER meets the requirements.

Nvidia (Mellanox) 800G OSFP SR8 to FiberMall 400G OSFP SR4

Test MethodsNvidia (Mellanox)FiberMall
MMA4Z00-NSOSFP-400G-SR4-FLT
MT2304FT11726MT233320018MT233320020
Check if Nvidia (Mellanox) 800G OSFP SR8 To FiberMall 400G OSFP SR4 module is linked up on the device.Link upLink upLink up
Test Duration72H72H72H
Pre-BER(<1e-6)YesYesYes
Post-BER (<1e-12)YesYesYes
ConclusionMellanox 800G OSFP SR8 To FiberMall 400G OSFP SR4 module in Nvidia (Mellanox) 9790 switch and Nvidia (Mellanox) ConnectX-7 NIC Link up, BER meets the requirements.

FiberMall 800G OSFP SR8 to Nvidia (Mellanox) 400G Q112 SR4

Test MethodsFiberMallNvidia (Mellanox)
OSFP-800G-SR8DMMA1Z00-NS400
MT233320036MT2305FT04288MT2302FT20690MT2252FT06234MT2307FT01145
Check if FiberMall 800G OSFP SR8 To Nvidia (Mellanox) 400G Q112 SR4 module is linked up on the device.Link upLink upLink upLink upLink up
Test Duration72H72H72H72H72H
Pre-BER(<1e-6)YesYesYesYesYes
Post-BER (<1e-12)YesYesYesYesYes
ConclusionFiberMall 800G OSFP SR8 To Mellanox 400G Q112 SR4 module in Nvidia (Mellanox) 9790 switch and BlueField-3 DPU Link up, BER meets the requirements.

Nvidia (Mellanox) 800G OSFP SR8 to FiberMall 400G Q112 SR4

Test MethodsNvidia (Mellanox)FiberMall
MMA4Z00-NSQSFP112-400G-SR4
MT2304FT11726MT233250003MT233250018MT233250015MT233250020
Check if FiberMall Q 400G Q112 SR4 To Nvidia (Mellanox) 400G Q112 SR4 module is linked up on the device.Link upLink upLink upLink upLink up
Test Duration72H72H72H72H72H
Pre-BER(<1e-6)YesYesYesYesYes
Post-BER (<1e-12)YesYesYesYesYes
 ConclusionMellanox 800G OSFP SR8 To FiberMall  400G Q112 SR4 module in Nvidia (Mellanox) 9790 switch and BlueField-3 DPU Link up, BER meets the requirements.

Leave a Comment